Open Access
Numéro |
EPJ Web Conf.
Volume 253, 2021
ANIMMA 2021 – Advancements in Nuclear Instrumentation Measurement Methods and their Applications
|
|
---|---|---|
Numéro d'article | 09001 | |
Nombre de pages | 5 | |
Section | Environmental and Medical Sciences | |
DOI | https://doi.org/10.1051/epjconf/202125309001 | |
Publié en ligne | 19 novembre 2021 |
- Ankerhold, U., Hupe, O. and Ambrosi, P. “Deficiencies of active electronic radiation protection dosemeters in pulsed fields.” Radiat. Prot. Dosim, vol. 135, no. 3, pp. 149–153, 2009, DOI:10.1093/rpd/ncp099. [CrossRef] [PubMed] [Google Scholar]
- Gotz, M. “Dosimetry of highly pulsed radiation fields.” HZDR, Dresden-Rossendorf, Germany. HZDR-90, 2018. Available: https://www.hzdr.de/publications/Publ-27317. [Google Scholar]
- “EPD TruDose for dosimetry in short pulsed X-ray fields using the example of industrial pulsed X-ray source XR-200.” Available: https://www.thermofisher.com/order/catalog/product/EPDTRUDOSE#/EPDTRUDOSE. [Google Scholar]
- Friedrich, S. and Hupe, O. “Dose measurements in pulsed radiation fields with commercially available measuring components.” Radiat. Prot. Dosim., vol. 168, no.3, pp. 322–329, 2016, DOI:10.1093/rpd/ncv355. [Google Scholar]
- International Commission on Radiation Units and Measurements (ICRU) “Determination of Dose Equivalents Resulting from External Radiation Sources (Report 39)”. Journal of the ICRU, vol. os20, no. 2, Feb. 1985, DOI: 10.1093/jicru/os20.2.Report39. [Google Scholar]
- A.R. Beierholm et al., “Investigation of linear accelerator pulse delivery using fast organic scintillator measurements.” Radiat. Meas., vol. 45, no. 3-6, pp. 668-670, Mar.-Jul. 2010. DOI: 10.1016/j.radmeas.2009.11.023. [CrossRef] [Google Scholar]
- Horst, F., Fehrenbacher, G. and Zink, K. “On the neutron radiation field and air activation around a medical electron LINAC.” Radiat. Prot. Dosim., vol. 174, no. 2, pp. 147-158, 2017, DOI:10.1093/rpd/ncw120. [Google Scholar]
- Keehan, S. et al. “Dose and gamma-ray spectra from neutron-induced radioactivity in medical linear accelerators following high-energy total body irradiation.” Radiat. Prot. Dosim., vol. 172, no. 4, pp. 327-332, 2016, DOI:10.1093/rpd/ncv480. [CrossRef] [PubMed] [Google Scholar]
- Behrens, R., Pullner, B. and Reginatto, M. “X-ray emission from materials processing lasers.” Radiat. Prot. Dosim., vol. 183, no. 3, pp. 361–374, 2019, DOI:10.1093/rpd/ncy126. [CrossRef] [PubMed] [Google Scholar]
- J.H. Hubbell and S.M. Seltzer, “Tables of X-ray mass attenuation coefficients and mass energy-absorption coefficients 1 keV to 20 MeV for elements Z=1 to 92 and 48 additional substances of dosimetric interest.” NISTIR, Gaithersburg, MD, USA. Tech. Rep. NISTIR-5632, 1995. [Google Scholar]
- “DAQ125 Firmware (datasheet).” Serious Dynamics. [Google Scholar]
- K. Roemer et al., “A technique for measuring the energy resolution of low-Z scintillators.” 2009 IEEE Nucl. Sci. Symp. Conference Record (NSS/MIC), Orlando, FL, 2009, pp. 6-11, DOI: 10.1109/NSSMIC.2009.5401909. [Google Scholar]