Open Access
Numéro |
EPJ Web Conf.
Volume 153, 2017
ICRS-13 & RPSD-2016, 13th International Conference on Radiation Shielding & 19th Topical Meeting of the Radiation Protection and Shielding Division of the American Nuclear Society - 2016
|
|
---|---|---|
Numéro d'article | 01012 | |
Nombre de pages | 4 | |
Section | 1. Nuclear Data, Radiation Detection, Measurements & Dosimetry | |
DOI | https://doi.org/10.1051/epjconf/201715301012 | |
Publié en ligne | 25 septembre 2017 |
- Hadrontherapy facilities worldwide in operation. www.ptcog.ch, updated 09-Nov-2014) [Google Scholar]
- Raju MR, Amols HI, Bain E, Carpenter SG, Cox RA, Robertson JB, “A heavy particle comparative study. Part III. OER and RBE”, Br. J. Radiol., 51, 712-719 (1978) [CrossRef] [PubMed] [Google Scholar]
- Curtis SB, “The OER of mixed high- and low-LET radiation”, Radiat Res 65, 566-572 (1976). [PubMed] [Google Scholar]
- S. Agosteo, G.A.P. Cirrone, P. Colautti, G. Cuttone, G. D’Angelo, A. Fazzi, M.V. Introini, D. Moro, A. Pola, V. Varoli. “Study of a silicon telescope for solid state microdosimetry: Preliminary measurements at the therapeutic proton beam line of CATANA” Radiat. Meas. 45, 1284-1289 (2010). [Google Scholar]
- V. Cesari et al., Nanodosimetric measurements with an avalanche confinement TEPC, Radiation Protection Dosimetry 99 (1-4): 337-342 (2002). [Google Scholar]
- S. Rollet, M. Angelone, G. Magrin, M. Marinelli, E. Milani, M. Pillon, G. Prestopino, C. Verona, G. Vrrona-Rinati. “A novel microdosimeter based upon arificial single crystal diamond”, Nucl.Sci. IEEE Trans. 59, 2409-2415 (2012). [CrossRef] [Google Scholar]
- Meas. 45, 1284-1289 [Google Scholar]
- L. De Nardo, V. Cesari, G. Donà, G. Magrin, P. Colautti, V. Conte and G. Tornielli, “Mini-TEPCs for radiation therapy”, Rad. Prot. Dos. 108, 345-352 (2004). [CrossRef] [Google Scholar]
- L. De Nardo, V. Cesari, N. Iborra, V. Conte, P. Colautti, J. Héreault, G. Tornielli, P. Chauvel. “Microdosimetric assessment of Nice therapeutic proton beam biological quality, Physica Medica XX, 71-77 (2004). [Google Scholar]
- S. Rossi, “The National Centre for Oncological Hadrontherapy (CNAO): Status and perspectives”, Physica Medica 31, 333-351 (2015). Doi: 10.1016/j.ejmp.2015.03.001. [CrossRef] [Google Scholar]
- S. Giordanengo, M.A. Garella, F. Marchetto, F. Bourhaleb, M. Ciocca, A. Mirandola, V. Monaco, M.A. Hosseini, C. Peroni, R. Sacchi, R. Cirio, M. Donetti, “The CNAO dose delivery system for modulated scanning ion beam radiotherapy” Med Phys. 42, 263-275 (2015). doi: 10.1118/1.4903276 [PubMed] [Google Scholar]
- Mirandola A, Molinelli S, Vilches Freixas G, Mairani A, Gallio E, Panizza D, Russo S, Ciocca M, Donetti M, Magro G, Giordanengo S, Orecchia R. Dosimetric commissioning and quality assurance of scanned ion beams at the Italian National Center for Oncological Hadrontherapy. Med Phys. 2015 42 (9): 5287-300. [Google Scholar]
- D. Conte, D. Moro, B. Grosswendt, P. Colautti. Lineal energy calibration of mini tissue-equivalent gas-proportional counters (TEPC), in Multidisciplinary Applications of Nuclear Physics With Ion Beams. AIP Conference collection, 2013, pp. 171-178. [Google Scholar]
- IAEA 2008. Relative Biological Effectiveness in Ion Beam Therapy. Technical report 461 [Google Scholar]